• FEATURES
  • TYPES OF TRANSFORMERS
  • TECHNICAL SPECIFICATIONS

AVAILABLE IN

  • Auto Transformer
  • Buck Boost Transformer
  • Control Transformer
  • Drive Isolation Transformer
  • Low Voltage Lighting Transformer
  • Stray Field Transformer
  • K Rated Transformers
  • Power Transformers

TRANSFORMER FEATURES

  • Constructed to withstand + 10% continuous voltage fluctuations as a standard
  • Conform to BIS and international standards
  • Insulation class ‘E’ to ‘H’ as specified
  • High Quality Lamination and Conductors ensure Low Losses
  • Impregnated with International Quality Resins and Varnishes
  • Chemically treated and plated fasteners and hardware to avoid corrosion
  • Terminals shrouded for safety
  • Shields inserted as per customers special requests
  • Saturation and Linearity as per specifications
  • Sheet Metal Enclosures as per required IP class of protection on request
  • Incoming Components and Materials inspected before use
  • In Process Controls and Production Testing Systems for all products
  • All testing carried out by Calibrated Test Equipment
  • Rugged construction for maintenance free performance

TYPES OF TRANSFORMERS

Control Transformers

  • Range : 50VA to 10KVA
  • Can withstand wide voltage variations
  • Efficiency : Higher than 94%

High Current Rectifier Transformers

  • Range : Up to 4000 Amp.
  • Copper & Aluminum Conductors
  • Multiple Secondary Windings
  • Efficiency : 97% or more

Multi-Tapping Transformers

  • Range : Up to 600KVA
  • Copper & Aluminum Conductors
  • Up to 32 Secondary's
  • Efficiency : 97% or more
  • Suitable for wide voltage fluctuations

Auto Transformers

  • Range : Up to 500KVA
  • Used when isolation is not required between Input & Output
  • It has only one winding to step up or step down the voltage
  • Smaller and cheaper than Isolation Transformers

UPS Transformers

  • Range : Up to 300KVA
  • Single Phase and Three Phase
  • Copper & Aluminum Conductors
  • Split or Double wound for impedance matching.
  • Zigzag winding

Power & Isolation Transformers

  • Range : up to 750KVA
  • Continuous operation under voltage fluctuations
  • K-Rated Transformers for harmonic Loads
  • Ultra-Isolation feature on request
  • Three Phase Input & single phase output available
  • Efficiency : 96 to 98%

CHOKES

Motor Drive Chokes

  • Range : Up to 4000 Amp
  • Copper & Aluminum Conductors
  • Low Power Loss for continuous operation
  • High overload capacity

Filter Chokes

  • Range : Up to 4000 Amp
  • Compact Construction
  • Suitable for 6 & 12 pulse Filtration
  • Low Noise and high saturation margin

Reactors

Detuned Reactors

  • Range : 1KVA to 200KVAr
  • Operating Voltage : Up to 750 Volts
  • Protection Factor : 0.2% to 14%
  • Copper & Aluminum Conductors
  • Compact Design for space saving

PFC Reactors

  • Range : Up to 300KVAr
  • Single Phase and Three Phase
  • Copper & Aluminum Conductors

TECHNICAL SPECIFICATIONS

Specification Details
Range 50VA To 1000 KVA
Frequency 50 / 60 Hz
Winding Material Copper & Aluminum
Phase Single & Three Phase
Core Material CRGO / CRNO / Amorphous / Ferrite
Insulation System Up To 210°C ( 115°C Temp. Rise )